MS-40GT Dry Portable Helium Leak Detector
The ATEQ MS-40GT DRY is fully automatic, easy to use, and highly accurate. These advanced leak detectors are ideal for a broad range of applications including clean, oil-free testing,…
MS-40GT : APPLICATIONS
- Beverage/Food Containers
- Dry Cleanroom
- Electronics
- Freeze Dryer Applications
- Gas Distribution Lines
- Li-ion Batteries
- Particle Accelerators
- Pharmaceuticals
- Process Chambers
- Quartz Crystal Packages
- Semiconductors
- UHV Systems & Hardware
MS-40GT: FEATURES
PERFORMANCE | ||
---|---|---|
Sensitivity vacuum* |
Sensitivity sniffing |
Startup Time |
4.0×10-11 (atm-cc/sec) |
5.0~10-7 Atm-cc/second |
Less than 3 minutes |
Main Features
- Touch-Screen Graphical User Interface
- Highest accuracy in the industry
- Simple one-button start-up
- Built-in diagnosis for trouble- free maintenance
- Fully automatic tuning and calibration
- Internal NIST-traceable temperature compensated calibrator
- Fast, non-destructive leak testing assures longer life and greater protection for your product
- Allows testing for the smallest leaks at the highest pressures
- RS-232 port provides for external control
- Remote control
- Cleanroom model, Optional
MS-40GT: SPECIFICATIONS
Characteristics
- Leak Measurement Range: 1.0 x 10-3 to 4.0 x 10-11 (10 atm cc/sec to 4.0
- Leak Ranging: Auto/Manual
- Response Time: <3
- Resolution for 4He *: 14
- Mass Spectrometer Tube: 180° deflection; dual-magnetic sector/stainless steel construction
- Auto-tuning: Yes
- Auto-calibration: Internal – yes; External – auto
- Auto-zeroing: Yes
- Reject set-point: Yes
- Built-in calibrated leak: Yes
- NIST traceable: Yes
- Temperature compensated: Yes
- He scan: Yes
- Filaments: 2
- Maximum Operating Pressure: 7.5, 760 w/ext roughing option
- Display: Alpha/Numeric
- Units: atm cc/s, mbar*l/s, Pa*M3/sec
- Background Compensation: Continuous automatic compensation for system background
- Testable Masses: 3 and 4
Flexible Communication format
- Printer Port: Yes
- RS-232C: Yes
- Remote Control: Yes
Technical Specifications | |
---|---|
Vacuum Mode | Direct, reverse or combination flow |
Roughing Pump | 1.2 Mechanical Foreline/Rouging Pump Built-in dry 16 cfm dual stage diaphragm/molecular drag pump High |
High Vacuum Pump | Pump 53 L/sec |
Vacuum Gaughing | Pirani: Test Port and Foreline Ion: Hig Vacuum |
Cold Trap | MS-50GT- N/A MS-50GT Dry- N/A |
Power | 115/50-60/8; 230-240/50-60/5 100/50-60/8 |
Weight | MS-40GT – 87 (39.5) MS-40GT Dry – 96 (43.6 kg) |
Dimensions | (W x H x D):20.5 x 15 x 14 (52.7 x 38.1 x 35.6) |
Test Cup, UFT Option UFT(Ø x D) |
Dimensions (in mm) W344*H395*D618 |
Test Port Connection | NW25 |
MS-40GT: FACTSHEETS
Detailed information about the MS-40GT including features, specifications, etc.
MS-40GT Brochure – English